Language

86-15868381495
  • Conceptual differences and laying requirements of fire-resistant cables, flame-retardant cables, fire-resistant cables, and mineral-insulated non-combustible cables

    Conceptual differences and laying requirements of fire-resistant cables, flame-retardant cables, fire-resistant cables, and mineral-insulated non-combustible cables

    At present, there is no corresponding national standard definition for fireproof cables in the country. The cable industry is used to refer to cables with certain fireproof performance such as flame-retardant cables, fire-resistant cables, and mineral-insulated non-combustible cables as fire-resista... READ MORE

    09-02-2022 Industry News
  • Microphone Cable Process Features

    Microphone Cable Process Features

    XLPEDue to the above-mentioned twisted pair characteristics, when the microphone cable is welded with the corresponding Canon connector, the twisted pair will cross at 2.3 feet, which is easy to cause the plastic to melt during welding and cause a short circuit. Therefore, some manufacturers have in... READ MORE

    27-01-2022 Industry News
  • Cable resistance calculation

    Cable resistance calculation

    The DC standard resistance of the cable can be calculated according to the following formula:R20=ρ20(1+K1)(1+K2)/∏/4×dn×10In the formula: R20——the branch current standard resistance of the cable at 20℃ (Ω/km)ρ20——The resistivity of the wire (at 20℃) (Ω*mm/km)d——diameter of each core wire (mm)n——the ... READ MORE

    20-01-2022 Industry News
  • What are the types of cables?

    What are the types of cables?

    Composition and OrderThe model composition and sequence of wires and cables are as follows:1: Category, use][2: Conductor][3: Insulation][4: inner sheath][5: Structural features][6: outer sheath or derivative][7: Using Features]Items 1-5 and 7 are represented by pinyin letters, polymer materials are... READ MORE

    13-01-2022 Industry News
  • Performance index of twisted pair(2)

    Performance index of twisted pair(2)

    3. DC resistanceThe DC loop resistance consumes part of the signal and converts it into heat. It refers to the sum of the resistance of a pair of wires. The DC resistance of the 11801 twisted pair must not be greater than 19.2 ohms. The difference between each pair should not be too large (less than... READ MORE

    07-01-2022 Industry News
  • Performance index of twisted pair (1)

    Performance index of twisted pair (1)

    For twisted-pair cables, users are most concerned about several indicators that characterize its performance. These indicators include attenuation, near-end crosstalk, impedance characteristics, distributed capacitance, DC resistance, etc.1. AttenuationAttenuation is a measure of signal loss along t... READ MORE

    29-12-2021 Industry News
  • Twisted pair production steps

    Twisted pair production steps

    The following introduces the most basic method of making straight-through Category 5 cables. The methods of making other types of network cables are similar. The only difference is that the jumper method is different.Step 1: Use twisted pair network cable pliers (of course, you can also use other cu... READ MORE

    23-12-2021 Industry News
  • Classification of twisted pair(3)

    Classification of twisted pair(3)

    5) Category 5 cable (CAT5): This type of cable has increased winding density and a high-quality insulating material. The maximum frequency bandwidth of the cable is 100MHz, and the maximum transmission rate is 100Mbps. It is used for voice transmission and the maximum transmission rate is 100Mbps da... READ MORE

    17-12-2021 Industry News
  • Twisted pair classification (2)

    Twisted pair classification (2)

    Classification according to frequency and signal-to-noise ratioTwisted-pair wires are commonly classified into three types, five types and super five types, and six types. The former has a small diameter and the latter has a thick diameter. The specific models are as follows:1) Category 1 line (CAT1... READ MORE

    10-12-2021 Industry News
  • Classification of twisted pair(1)

    Classification of twisted pair(1)

    Classified according to whether there is a shielding layerAccording to whether there is a shielding layer, twisted pair is divided into shielded twisted pair (STP) and unshielded twisted pair (UTP).The shielded twisted pair has a metal shield between the twisted pair and the outer insulating sheath.... READ MORE

    08-12-2021 Industry News